The PTC-V is a state-of-the-art, fully automated Purge and Trap (P&T) concentrator integrated with a 100-position autosampler, engineered for the precise extraction of Volatile Organic Compounds (VOCs) from solid and liquid samples.
Details
VOC Sample Preparation with Built-in 100-Position Autosampler
Designed for seamless hyphenation with any brand of Gas Chromatography (GC) or Gas Chromatography-Mass Spectrometry (GC-MS) systems, the PTC-V delivers unparalleled analytical efficiency. Thanks to its patented moisture removal technology, precise Electronic Flow Control (EFC/AFC), and superior trap desorption rates, it minimizes water interference and ensures highly reproducible, stable, and accurate VOC analysis.

Applications & Compliance
Ideal for high-throughput laboratories, the PTC-V is widely used in:
- Environmental Analysis: Drinking water, wastewater, and soil organic pollutant testing.
- Food & Beverage: Analysis of volatile flavor compounds and odor components.
The system fully complies with stringent environmental analytical standards, including:
- HJ639-2012 (Water Quality – Determination of VOCs by P&T/GC-MS)
- HJ686-2014 (Water Quality – Determination of VOCs by P&T/GC)
- HJ605-2011 (Soil and Sediment – Determination of VOCs by P&T/GC-MS)
Key Features
Universal & Fully Automated
Universal Compatibility: Plug-and-play integration with any GC or GC-MS brand on the market.
Unattended Operation: Simply load vials into the 100-position tray; the comprehensive software handles all operations automatically, ensuring exceptional sample reproducibility.
Automated Internal Standards: Automatically adds internal standards to simplify workflows.
Intuitive Touchscreen: A large, built-in LCD touchscreen allows for real-time monitoring of temperatures and operational commands.
Smart Synchronization: Provides a synchronous interface to simultaneously start the GC and workstation upon injection.
Superior Thermal & Cooling Technology
- Advanced Peltier Cooling: The analytical trap utilizes thermoelectric (Peltier) cooling combined with air cooling, achieving temperatures as low as -30°C (at 20°C ambient) to satisfy highly demanding low-temperature enrichment requirements.
- Ultra-Fast Desorption: Direct resistance heating of the trap ensures a blistering heating rate of >3000°C/min, maximizing peak sharpness and resolution.
Maximum Contamination & Moisture Control
- Patented Moisture Management: Significantly reduces the transfer of water vapor to the GC/GC-MS, protecting your analytical columns and detector.
- Smart Foam Sensor: Built-in sensor detects foaming inside the purge tube, instantly protecting the sample lines and the entire analytical system from contamination.
- Inert Sample Pathways: All sample lines are constructed from PEEK or silanized inert stainless steel to eliminate carryover and active sites.
- Zero Cold Spots: All transfer lines and the 6-port valve are temperature-controlled, eliminating cold spots and preventing sample loss.
- Isolated Backflush: Trap and purge tube backflush gas paths are separated. Desorbed compounds from the trap are physically prevented from flowing back into the purge tube, eliminating cross-contamination.
- Heated Water Rinse: Supports hot distilled water rinsing of lines and the purge tube, alongside customizable cleaning cycles for both the sampling needle and purge tube.
- Direct Solid Sample Processing: Solid sample vials can be heated and injected with distilled water directly for in-vial magnetic stirring and purging.
Technical Specifications
| Parameter | Specification |
| Sample Capacity | 100 positions (compatible with standard 40ml VOA vials) |
| Flow Control | Auto Flow Controller (AFC), Range: 5 ml/min to 500 ml/min |
| Internal Standard | Automated addition supported |
| Cooling Technology | Thermoelectric (Peltier) cooling; Minimum temp: -30°C |
| Trap Desorption Temp | 50°C to 400°C (Heating rate >3000°C/min; cools from 250°C to 35°C in <90s) |
| Purge Tube Temp | Ambient to 90°C (Accuracy: ±1°C) |
| Transfer Line Temp | 50°C to 250°C (Accuracy: ±1°C) |
| 6-Port Valve Temp | 50°C to 220°C (Accuracy: ±1°C) |
| Moisture Trap Temp | Ambient to 400°C |
| Sample Needle Temp | 50°C to 220°C (Accuracy: ±1°C) |
| Rinse Water Temp | Ambient to 90°C (Accuracy: ±1°C) |
| Solid Sample Setup | Heating: Ambient to 90°C (±1°C); Mixing: 5ml water with magnetic stirring |
| Glassware | 5ml fritted purge tube (Standard); 25ml purge tube (Optional) |
| Trap Dimensions | Stainless steel, Φ3mm × 180mm × 0.1mm thickness |
| Timing Range | 1 sec to 99 min 59 sec (Timing error: <0.1%) |
| Max Gas Pressure | ≤ 0.6 MPa |
| Sync Signal Output | Dual 1-2 second switch outputs |
| Max Power | < 1000 VA |
| Dimensions (H×W×D) | 560 mm × 605 mm × 860 mm |
Operating Conditions
- Power Supply: 220VAC ±22VAC, 50Hz ±0.5Hz
- Backflush Carrier Gas Pressure: ≤ 0.4 MPa
- Ambient Temperature: +5°C to +35°C
- Relative Humidity: ≤ 85%
FAQ
-
Q: How to get more information about the product?A: You can contact us via email at info@zhpmchem.com or WhatsApp at +8618321309391 for more information about our products and company.
-
Q: Does the product meet our requirements regarding formulation, equipment, and processing?A: Yes, we will adjust the product formulation to your specific needs, ensuring it meets your processing requirements.